ATEX and hazardous area CCTV
Hazardous area CCTV from AIS, for gas, dust and chemical environments
ATEX and IECEx certified explosion proof cameras for Zone 1, 2, 21 and 22, designed, installed and maintained by our CompEx certified engineers. Free site survey and a fixed written quote.
Installing commercial security since 2000. CompEx certified engineers.
- Since 2000
- Trading
- CompEx
- Certified engineers
- ATEX and IECEx
- Certified cameras
- Zones 1, 2, 21, 22
- Gas and dust
- 316L
- Stainless steel
- 3 years
- Equipment warranty
In summary
If you need CCTV in a hazardous area, the question is who to trust with it. AIS supplies, installs and maintains certified explosion proof camera systems for gas, dust and chemical environments, with every installation carried out by our CompEx certified engineers.
Our range covers static and PTZ camera systems up to 4K, in 316L stainless steel for corrosive sites or aluminium alloy where budgets are tighter. Each camera is matched to the zone, gas or dust group and temperature class on your area classification drawings, and handed over with its certification for your DSEAR file.
What we do
Hazardous area CCTV, from specification to inspection
One team for the whole project, with all installation work carried out by our CompEx certified engineers.
-
Specification
Cameras selected from your area classification drawings for each zone, gas or dust group and temperature class.
-
Supply
ATEX and IECEx certified cameras, junction boxes, conduit and brackets, delivered with their certificates.
-
Installation
Installed by our CompEx certified engineers to BS EN 60079-14.
-
Commissioning
Cameras set up, tested and integrated with your site's CCTV on one platform.
-
Inspection and maintenance
Inspection to BS EN 60079-17 combined with CCTV maintenance in one contract.
-
Supply and commission
Certified equipment supplied and commissioned for your own CompEx certified engineers to install.
Zones
Zones we work in
Every camera is certified for its zone and matched to the gas or dust group and temperature class on your drawings.
-
Zone 1 (gas)
An explosive gas atmosphere is likely to occur during normal operation.
-
Zone 2 (gas)
An explosive gas atmosphere is not likely and, if it occurs, lasts only a short time.
-
Zone 21 (dust)
A combustible dust cloud is likely to occur during normal operation.
-
Zone 22 (dust)
A combustible dust cloud is not likely and, if it occurs, lasts only a short time.
Functions
What hazardous area CCTV is used for
-
Process monitoring
Control rooms supervise high-risk machinery, valves and pressurised reactions in real time, without sending staff into the zone.
-
Worker safety compliance
AI checks that PPE is worn, and live views give instant awareness to coordinate the response if an operator is incapacitated.
-
Minimising human footprint
Camera checks replace routine site walks and safety audits in restricted zones, cutting exposure to toxic gases, extreme heat and explosive dust.
-
Thermal defect detection
Dual-spectrum and radiometric thermal cameras spot friction, electrical hot spots and gas leaks before they reach ignition temperature.
-
Forensic troubleshooting
Footage of technical failures and leaks, protected in heavy-duty housings, for post-incident and regulatory investigations.
-
Perimeter security
24/7 surveillance of critical infrastructure such as fuel tank farms and offshore installations, where hazardous areas meet the security perimeter.
Applications
Where our cameras are used
-
Oil refineries and terminals
Tank farms, jetties and process units.
-
Fuel storage and distribution
Depots, loading gantries and pump areas.
-
Chemical plants
Reactors, storage and drum handling, with 316L stainless steel for corrosive atmospheres.
-
Gas processing and biogas
Compressor houses, digesters and gas holders.
-
Distilleries
Stills, bonded warehouses and filling halls where ethanol vapour is present.
-
Grain, flour and feed
Silos, mills and conveyors in dust zones.
-
Pharmaceuticals
Powder handling, solvent stores and process areas.
-
Paint and coatings
Spray booths, mixing rooms and solvent stores.
-
Waste and water
Waste water treatment, landfill gas and recycling plants.
Standard features
Standard features of every AIS hazardous area system
Included in every AIS system:
-
ATEX and IECEx certification
Cameras certified for Zone 1, 2, 21 and 22.
-
Up to 4K, static and PTZ
Fixed, varifocal and PTZ cameras, chosen for each position.
-
316L stainless steel or aluminium alloy
Anti-corrosion stainless steel for aggressive environments, aluminium alloy where budgets are tighter.
-
Clear images in low light
Detail kept at night and in poorly lit plant.
-
Certified accessories
Explosion proof junction boxes, flexible conduit and brackets that keep the whole installation compliant.
-
Remote support ready
With a support contract and an internet connection, our engineers can diagnose faults and adjust settings remotely, often without a site visit.
Compliance
Standards and compliance
Every AIS hazardous area installation is specified, installed and documented to the regulations and standards below.
-
DSEAR 2002
The Dangerous Substances and Explosive Atmospheres Regulations require hazardous areas to be zoned and equipment selected to suit. We specify from your area classification drawings.
-
ATEX and IECEx
Every camera carries certification for its zone, gas or dust group and temperature class, supplied with its documentation.
-
BS EN 60079-14 and 60079-17
The standards for installing and inspecting equipment in explosive atmospheres. Our CompEx certified engineers work to both.
Why AIS
Why sites choose AIS
One of our CompEx certified engineers reviews your area classification, walks the site with you and specifies a camera for each position. You get a specification and a fixed written quote, free and with no obligation.
Since 2000 we have installed security systems for factories, warehouses and large industrial complexes. We supply made-to-measure hazardous area CCTV for projects across the UK and overseas, including Malaysia, and all installation work is carried out by our CompEx certified engineers. If you have your own CompEx engineers, we can supply and commission the system for them to install.
Every installation carries a 1 year installation guarantee and a 3 year equipment warranty, and we price match like-for-like written quotes.
- Survey and specification by a CompEx certified engineer
- A camera specified for every zone and position
- Full installation, or supply and commission
- UK and international projects
- A fixed written quote with no obligation
Leasing
Spread the cost of hazardous area CCTV
Lease your system over three to five years, with inspection and maintenance included in the same agreement.
- No large up front outlay, so the system does not have to wait for a capital budget
- Fixed monthly payments you can plan against for the whole agreement
- Lease payments are normally treated as an operating cost rather than capital spend
- Maintenance can be included in the same agreement
- Budget for the system you actually need rather than cutting equipment to hit a figure
- Upgrade at the end of the term instead of running equipment past its life
Questions
Hazardous area CCTV questions
Why choose AIS for hazardous area CCTV?
We supply made-to-measure hazardous area CCTV for gas, dust and chemical environments, and all installation work is carried out by our CompEx certified engineers. Every system is specified from your area classification, documented for your DSEAR file and backed by a 1 year installation guarantee and a 3 year equipment warranty.
Which zones do your cameras cover?
Zone 1 and Zone 2 for gas, and Zone 21 and Zone 22 for dust. Each camera is matched to the gas or dust group and temperature class on your area classification drawings.
What is the difference between ATEX and IECEx?
ATEX is the European certification for equipment used in explosive atmospheres; IECEx is the international equivalent. Our cameras carry both, and we supply the certificates with every installation.
Do you have cameras for corrosive environments?
Yes. Our 316L stainless steel cameras have anti-corrosion surface treatment for chemical plants, coastal sites and washdown areas. Aluminium alloy models suit less aggressive environments at a lower cost.
Can our own engineers install the cameras?
Yes, if they are CompEx certified. We can supply and commission the cameras and recording system while your engineers install them.
Why do sites install hazardous area CCTV?
The six most common uses are process monitoring from the control room, checking PPE and worker safety, reducing the number of people entering hazardous zones, thermal detection of hot spots and gas leaks, forensic troubleshooting after failures or leaks, and perimeter security for critical infrastructure.
How are hazardous area cameras maintained?
They need inspection under BS EN 60079-17 as well as normal CCTV maintenance. We combine both in one maintenance contract.
Do you cover the rest of the site as well?
Yes. Most sites also need standard cameras, alarms and access control in safe areas. See commercial CCTV and industrial CCTV systems.
Book a free hazardous area CCTV survey
Send us your area classification drawings or book a survey with one of our CompEx certified engineers. You will receive a camera specification and a fixed written quote. Free, with no obligation.
- We reply the same working day
- Survey visits arranged around your shifts and permits
- CompEx certified engineers
- 1 year installation guarantee and 3 year equipment warranty
- Spread the cost over three or five years
Accredited and audited
Certified partners